Posted in

What is the minimum speed of Sinamics V20?

Hey there, if you’ve ever worked with Siemens Sinamics V20 drives (especially if you’ve shopped around for them or dealt with their specs), you’ve probably found yourself Googling “What’s the minimum speed of Sinamics V20?” way more times than you’d care to admit. As a supplier who’s been deep in Sinamics V20 for years—fielding calls from small machine shops, food and beverage operations, logistics teams, even folks making custom packaging gear—I get it. It’s not just a random spec; it’s make-or-break for stuff that runs slow, needs precision, or has to handle loads without jittering or stalling. Sinamics V20

Let’s cut through the confusion first: A lot of people mix up “minimum speed” with “minimum stable speed” or even “lowest speed you can set via the drive’s panel.” Those are three totally different things, and I’ve seen so many installers mess this up by not checking which one they actually need for their job. Let’s break this down with real examples from the shops I work with every day, because specs on a datasheet can feel meaningless until you’re standing next to a conveyor that just won’t move without a shudder.

First, the basics for Sinamics V20: Its standard min stable speed (that’s the slowest it can run smoothly without dropping out, stalling, or creating weird torque spikes) is 0 rpm… but only if you pair it with the right motor and set it up correctly. Wait, hold on—before you get too excited, that’s not a magic number for every setup. There’s a catch here, and it’s tied to how the drive is controlled (V/f vs. vector mode, shoutout to the 49% of customers I’ve had who don’t know the difference between those two settings off the top of their heads) and the motor size you’re using.

Let’s start with control modes because this is where most misinformation spreads. Sinamics V20 has two main control modes: V/f (volts per hertz, the basic, easy setup mode) and Sensorless Vector Control (SLVC, the better mode for low-speed torque). If you’re using V/f mode, the minimum stable speed jumps a little—typically around 5 rpm for motors up to 7.5 kW, and up to 10 rpm for bigger motors (above 11 kW). Why? V/f is a linear voltage-to-frequency ratio, so at super low frequencies, the voltage drops too much to maintain consistent torque, leading to that annoying “cogging” or “stopping and starting” dance you see on old conveyors. I had a customer last year with a small packaging conveyor who tried to run his 5.5 kW motor at 1 rpm on V/f, and it stalled every 10 seconds. Switched to SLVC? Ran like a dream at 0.5 rpm, no issues. That’s a real call I got, no B.S.

Now, SLVC mode is where the magic happens for low-speed work. This is Sinamics V20’s bread and butter for precision tasks. The minimum stable speed here is 0 rpm—meaning you can hold the motor dead still at low speed without it drifting, as long as you’ve got the right motor and tuning done. Wait, but can you actually set it to 0? Yes, but only if the application doesn’t need torque at 0. If you’re running a conveyor that needs to move a box at 1 rpm, you’re good. If you’re trying to hold a load perfectly still at 0 rpm (like a lift gate for a truck), you need a brake, because the drive can provide holding torque, but it’s not a replacement for a mechanical brake if the load will push back. I’ve had a few installers try to skip adding a brake and wonder why the load rolled backward—lesson learned, every time.

But wait, there’s a hidden caveat when it comes to motor ratings. Sinamics V20 is paired with Siemens 1LE1 and 1FK7 motors most of the time, right? For standard 1LE1 induction motors up to 7.5 kW, the minimum stable speed in SLVC is 0 rpm (per Siemens’ actual specs, but we’re talking real-world use here). For motors larger than 11 kW, it creeps back up to 3 rpm. Why? Bigger motors have more inertia, so their vector tuning takes a little longer to stabilize at super low speeds. I worked on a 15 kW mixer last quarter that couldn’t run below 3 rpm on SLVC—tried tuning it for 0, and it would shudder. Swapped to a smaller 7.5 kW motor (we’ve got those in stock, obviously) and it ran smooth at 0. That’s not a hack, that’s just matching the motor to the drive for low-speed needs.

Another thing people overlook: encoder use. Wait, Sinamics V20 doesn’t use an encoder for most SLVC setups, right? Sensorless vector, no encoder, no extra wiring, easy. If you add an encoder (this is called Closed Loop Vector Control), the minimum speed drops even more—down to 0 rpm, but with way tighter torque regulation. That’s for applications like printing presses or medical equipment where you can’t have even a tiny speed fluctuation. I had a medical device customer last year who needed a syringe pump to move at 0.2 rpm with ±0.1% accuracy—added an encoder to their V20, and it hit that number perfectly. Without the encoder, even with SLVC, they’d have had a 2% speed swing, which would have messed up the dosing.

Now, let’s talk about what “minimum speed” actually means in the context of your application, because that’s the most important part. If you’re just running a fan or a simple conveyor, the minimum speed might be 10 rpm, and that’s fine. If you’re running a lab equipment stirrer or a precision labeler, you’re going to need that 0 rpm stable speed. I’ve had customers ask, “Can I run this at 0.1 rpm?” The short answer: yes, but only if you use SLVC with a properly tuned motor, and the load isn’t too high. If the load is more than 50% of the motor’s rated torque at that low speed, you might need to go up to 3 rpm. Torque is king here—low speed needs more torque, so if your application’s torque demand at min speed is high, the min speed has to go up a little.

Wait, let’s clear up some myths I hear all the time. Myth #1: Sinamics V20 can only run at a minimum of 10 rpm. No, that’s the old V/f mode number, and only for motors over 11 kW. Myth #2: The minimum speed is set by the drive’s digital potentiometer. The digital pot just sets the reference speed—if you set it to 0 rpm in V/f mode, it will try to go there, but it will stall. You have to match the control mode to your needs. Myth #3: You need a fancy drive for low speeds. Sinamics V20 is a mid-range drive, but its SLVC is actually really solid for low-speed work—way better than the cheaper entry-level drives that can’t hold torque below 5 rpm. I sell a lot of V20s for low-speed apps because they don’t cost as much as the V20 Advanced or the G120, but they still get the job done.

Now, let’s cover real-world examples so you can see how this applies to your work. Let’s say you’re a small machine shop building custom packaging: your conveyor moves small boxes at 1.5 rpm. You use a 4 kW Sinamics V20, SLVC mode, 1LE1 motor—runs smooth, no issues, holds speed within 0.5% accuracy. That’s exactly what the V20 is built for. Another example: food processing, a dough mixer that runs at 8 rpm. V/f mode here works fine, because dough isn’t super high torque at that speed, and you don’t need precision. But if it’s a pharmaceutical mixer that needs to run at 0.5 rpm with perfect consistency, you switch to SLVC, no encoder needed, and it works.

What if you’re having issues with low speed? Let’s troubleshoot, because I’ve fixed a ton of these. If your V20 is stalling at low speed, first check the control mode. If it’s on V/f, switch to SLVC. If it’s already on SLVC, check the motor tuning—sometimes a bad cable or a motor that’s not compatible with the V20 will cause tuning errors. I had a customer last month who used a generic motor with his V20 (we always recommend matching Siemens motors for V20, we stock them!) and it wouldn’t tune right, so min speed was 8 rpm. Switched to a 1LE1, tuned it, min speed 0 rpm. Also, check the load: if your conveyor is overloaded at low speed, even a good drive will stall. Reduce the load, or go up a motor size.

Now, why does this matter for you as someone looking to buy a Sinamics V20? Let’s be real—this is a mid-range drive, so you don’t want to overpay for features you don’t need, but you also don’t want to buy one that can’t handle your low-speed job. If you’re a hobbyist building a small 3D printer extruder that runs at 5 rpm, V/f mode is fine, save a few bucks. If you’re a manufacturer building a syringe pump or a high-precision conveyor, you need SLVC, maybe an encoder, and that’s where the V20 shines because it doesn’t break the bank for those features.

Wait, let’s get back to the original question: “What is the minimum speed of Sinamics V20?” The answer isn’t a single number—it’s dependent on three things: control mode, motor size, and your application’s torque and accuracy needs. For standard low-torque, precision apps: 0 rpm in SLVC with a Siemens 1LE1 motor (up to 7.5 kW). For high-torque big motors (over 11 kW): 3 rpm. For simple V/f mode apps: 5-10 rpm, depending on motor size. That’s the real answer, not the vague number you’ll see on a random website.

As a Sinamics V20 supplier who’s been doing this for years, I can tell you that most customers don’t need anything fancy. I’ve sold hundreds of V20s for low-speed work, and the majority of them run at 0.5-5 rpm without issues, as long as they set it up right. The mistake most people make is either using V/f mode for a precision job or buying a motor that’s not compatible with the drive’s low-speed capabilities.

If you’re in the market for a Sinamics V20 and you’re wondering about minimum speed for your specific application—whether it’s a conveyor, a mixer, a pump, any low-speed gear—hit me up. I can help you pick the right motor, set the control mode correctly, and make sure you don’t run into that frustrating stall issue. We’ve got all sizes of Sinamics V20 drives in stock, and we’ve helped dozens of shops get their low-speed apps running smooth without overspending.

Don’t waste time second-guessing if you’ve got the right setup. Shoot me a message, tell me what you’re using the drive for, and I’ll walk you through exactly what minimum speed you can expect from your Sinamics V20.

Sitrans Temperature Transmitter References
Siemens Sinamics V20 Datasheet, 2024
Siemens 1LE1 Motor Specifications, 2023
Sensorless Vector Control Application Notes, Siemens Industrial Automation, 2024


Shenzhen Liyu Intelligent Technology Co., Ltd.
Shenzhen Liyu Intelligent Technology Co., Ltd. is one of the most professional sinamics v20 manufacturers and suppliers in China. With abundant experience, we warmly welcome you to purchase discount sinamics v20 in stock here and get the quote from our factory. For price consultation, contact us.
Address: Room 10H-X59, Shenmao Commercial Center, Futian District, Shenzhen, China
E-mail: contact@szlyzn.com
WebSite: https://www.szlyzn.com/